A fix is available
APAR status
Closed as program error.
Error description
EAC getting violation code 8 running a non sclm delete in promote exit.
Local fix
Change RACF rule for dataset so EAC not invoked
Problem summary
**************************************************************** * USERS AFFECTED: All. * **************************************************************** * PROBLEM DESCRIPTION: RC=15 error when using FLMCMD to access * * SCLM controlled datasets. * **************************************************************** * RECOMMENDATION: IT IS RECOMMENDED THAT THIS SERVICE BE * * APPLIED. * **************************************************************** Depending on where the dataset OPEN was issued EAC may not navigate to the end of the TCB chain and therefore not identify all programs to be included in the HI-LO chain.
Problem conclusion
Do not stop at the 1st TCB level reached after OPEN processing but include all lower-level TCBs in building the HI-LO program chain.
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
OA29026
Reported component name
ENHC ACC CNTRL
Reported component ID
5697H5900
Reported release
110
Status
CLOSED PER
PE
YesPE
HIPER
YesHIPER
Special Attention
NoSpecatt
Submitted date
2009-05-21
Closed date
2009-08-10
Last modified date
2009-09-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA49290
Modules/Macros
HSSRELOD HSSRVALD HSSSBLD
Fix information
Fixed component name
ENHC ACC CNTRL
Fixed component ID
5697H5900
Applicable component levels
R110 PSY UA49290
UP09/08/14 P F908 ®
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSTQ62","label":"Enhanced Access Control for SCLM for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1","Edition":"","Line of Business":{"code":"LOB17","label":"Mainframe TPS"}}]
Document Information
Modified date:
02 September 2009