A fix is available
APAR status
Closed as program error.
Error description
While installing TEMS application support for a new fixpack level, the installer fails with rc = -3 (ERR_CONFIG_NOT_FOUND). This is because the installer is failing to find the port number when a variable has been inserted between the protocol and port number of the KDC_FAMILIES string (for example, adding in EPHEMERAL:Y). RECREATION STEPS: 1. Insert a variable such as EPHEMERAL:Y into the KDC_FAMILIES string between the port number and the protocol. For example, KDC_FAMILIES=IP.PIPE PORT:1918 now becomes KDC_FAMILIES=IP.PIPE EPHEMERAL:Y PORT:1918 2. Run the application support installer for the TEMS and it will fail. RELATED FILES/OUTPUT: ksminst.log shows the following at the end: (455B7942.0020-1EF0:ko4inst.cpp,974,"Installer610::init") port........<> (455B7942.0021-1EF0:ko4inst.cpp,975,"Installer610::init") cms name....<> (455B7942.0022-1EF0:ko4inst.cpp,976,"Installer610::init") binarch.....<win32> (455B7942.0023-1EF0:ko4inst.cpp,977,"Installer610::init") rc..........<-3> (455B7942.0024-1EF0:ko4inst.cpp,979,"Installer610::init") Exit: 0xFFFFFFFD (455B7942.0025-1EF0:ko4inst.cpp,2448,"main") Exiting with rc <-3> (455B7942.0026-1EF0:ko4inst.cpp,2449,"main") Exit: 0xFFFFFFFD APPROVER: bdm
Local fix
Rearrange the KDC_FAMILIES string so that the transport protocol (for example IP.PIPE) is immediately followed by the PORT number. Regardless of what the KDC_FAMILIES is set to in KBBENV, this change should actually be made in the Windows registry: 1) open the HKEY_LOCAL_MACHINE\Software\Candle\CMS\KMS\TEMS1\Environment key in the registry. 2) Change the value in KDC_FAMILIES from "IP.PIPE EPHEMERAL:Y PORT:1918" to "EPHEMERAL:Y IP.PIPE PORT:1918" instead 3) run the installation again and app. support should succeed
Problem summary
**************************************************************** * USERS AFFECTED: All TEMS users. * **************************************************************** * PROBLEM DESCRIPTION: Application support upgrades fail when * * EPHEMERAL:Y is added between the * * protocol and port number in the * * KDE_TRANSPORT environment variable. * **************************************************************** * RECOMMENDATION: Apply this PTF. * **************************************************************** Application support upgrades fail when KDE_TRANSPORT looks like this: IP.PIPE EPHEMERAL:Y PORT:1918 ... The problem does not exist when KDE_TRANSPORT looks like this: IP.PIPE PORT:1918 EPHEMERAL:Y ...
Problem conclusion
The code was change to correctly parse the value of the KDE_TRANSPORT environment variable.
Temporary fix
Comments
APAR Information
APAR number
OA26792
Reported component name
MGMT SERVER DS
Reported component ID
5608A2800
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-10-15
Closed date
2008-10-23
Last modified date
2008-12-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
KDSMAIN
Fix information
Fixed component name
MGMT SERVER DS
Fixed component ID
5608A2800
Applicable component levels
R620 PSY UA44295
UP08/11/05 P F811
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSRJ5K","label":"Tivoli Management Server for Distributed Systems on z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB17","label":"Mainframe TPS"}}]
Document Information
Modified date: