Skip to main content


OA19170: SIMPLIFY INSTALLATION/CUSTOMIZATION IN SA FOR ALL GDPS VERSION 3 PRODUCTS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • New Function
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: This APAR applies to all SA z/OS V3R1        *
    *                 customers.                                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: This APAR provides better integration   *
    *                      with any GDPS product by simplifying    *
    *                      the installation and customization.     *
    *                                                              *
    *                      This APAR also corrects the accuracy    *
    *                      of the value of C global                *
    *                      AOFINITIALSTARTTYP.                     *
    ****************************************************************
    * RECOMMENDATION: n/a                                          *
    ****************************************************************
    This APAR provides a simpler customization/setup when running
    GDPS. This is achieved by the following changes:
    o Completely restructured customization dialog for defining
      UET pairs including the possibility that more multiple user
      can access the entry type UET concurrently ('multi-user')
      (AOFG#NLS, AOFG#NL1, AOFGETYP, AOFGUET,  AOFHUET,  AOFGDYNU,
       AOFHUKD,  AOFGUETS, AOFGUKD,  AOFGUKDN, AOFHUKDN, AOFGUKDE,
       AOFHUKDE, AOFFZTBL, AOFTLP1,  AOFCMDS,  AOFFUET,  AOFFUETS,
       AOFFUET1, AOFFUET2, AOFFMUET, AOFFBUET, AOFFENA1, AOFFFUEY,
       AOFF@MS1, AOFF#TBD, AOFF#CHK, AOFFCREL, AOFCPTF,  AOFC1010,
       AOFD22,   AOFD40,   AOFD59,   AOFSUET,  AOFSUET1)
    
    o Sample policies *GDPS updated with required autooperators
      needed for GDPS/XRC and GDPS/GM, *HYPERSWAP includes some
      minor documentation updates
      (AOFJPDBD, AOFJPDBF)
    
    o Automatically call VPCEINIT during SA initialization if
      TOWER.SA=GDPS is specified, no need for defining VPCEINIT in
      SA policy database
      (AOFRACF0, AOFRAEXI)
    
    o New sample job INGESAF for RACF definitions of NetView tasks
      (INGESAF)
    
    o IOSHS0000I defined as UP message for GEOXHSWP in the SA
      created automation table INGMSG02
      (INGMDFLT, INGATCHG)
    
    Additionally some minor problems have been fixed:
    o incorrect text in PDB report for MCS flags
      (AOFFZTBL, AOFTLP1)
    
    o Parameter documentation was missing in AOFEXINT
    
    o loop during ACF REQ=REPL in AOFRACF1
    
    o incorrect value in cglobal AOFINITIALSTARTTYP
    

Problem conclusion

Temporary fix

  • n/a
    

Comments

  • n/a
    

APAR Information

  • APAR number

    OA19170

  • Reported component name

    SYSTEM AUTO Z/O

  • Reported component ID

    5698SA300

  • Reported release

    310

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function

  • Submitted date

    2006-12-06

  • Closed date

    2007-03-30

  • Last modified date

    2007-05-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA33332

Modules/Macros

  • AOFCMDA  AOFCMDS  AOFD22   AOFD40   AOFD59
    AOFEXINT AOFF#CHK AOFF#TBD AOFF@MST AOFF@MS1 AOFFAMCT AOFFBAM0
    AOFFBAM1 AOFFBAM2 AOFFBAM3 AOFFBAM4 AOFFBAM5 AOFFBUET AOFFCPTF
    AOFFCREL AOFFENA1 AOFFFUEY AOFFMUET AOFFPE01 AOFFPE02 AOFFPE05
    AOFFUET  AOFFUETS AOFFUET1 AOFFUET2 AOFFZINI AOFFZTBL AOFG#NLS
    AOFG#NL1 AOFGDYNU AOFGETYP AOFGUET  AOFGUETS AOFGUKD  AOFGUKDE
    AOFGUKDN AOFHUET  AOFHUKD  AOFHUKDE AOFHUKDN AOFJPDBD AOFJPDBF
    AOFRACF0 AOFRACF1 AOFRAEXI AOFSUET  AOFSUET1 AOFTLP1  AOFT0ATD
    AOF02    DSIAOF02 INGATCHG INGCMD   INGESAF  INGPSILM INGPYBLD
    INGPYENC INGRDYNO
    

Publications Referenced
SC33826101SC33826103   

Fix information

  • Fixed component name

    SYSTEM AUTO Z/O

  • Fixed component ID

    5698SA300

Applicable component levels

  • R310 PSY UA33332

       UP07/04/05 P F704

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

Copyright and trademark information

IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.

Rate this page

Please take a moment to complete this form to help us better serve you.

This material provides me with the information I need.






This material is clear and easy to understand.






Did the information help you to achieve your goal?

What updates, improvements, or related information would you like to see in this document?

Your response will be used to improve our document content. Requests for assistance, if applicable, should be submitted through your normal support channel as we cannot respond from this site.


Input the verification number to submit feedback:



Maintenance Window

Unscheduled Maintenance Window

There is no unscheduled maintenance scheduled at this time.

Document information

Product categories:

Software

Systems and Asset Management

Systems Performance

IBM Tivoli System Automation for z/OS


Software version:

310


Reference #:

OA19170


IBM Group:

Software Group


Modified date:

2007-05-01

Translate my page