LI77329: PU-LU STATUS REMAINS ACTIVE AFTER NETWORK INTERFACE IS STOPPED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Ø
    The value for the idle_timeout parameter is not being honored
    and, therefore, outages on the link are not being detected
    properly.  This is causing the PU-LU status to appear as still
    active.
    
    
    
    
    
    
    
    
    Additional Symptom(s) Search Keyword(s):
    

Local fix

  • Ø
    none
    

Problem summary

  • LLC2 link fails to timeout if the partner system fails suddenly
    (adapter fault or wire disconnect). The link will only then
    timeout when an application tries to send data on the link.
    

Problem conclusion

  • Corrected the idle timer code. The problem was introduced at CS
    Linux 6.2.2.0 and does NOT apply to CS/AIX.
    

Temporary fix

Comments

APAR Information

  • APAR number

    LI77329

  • Reported component name

    CS FOR LINUX

  • Reported component ID

    5724I3300

  • Reported release

    623

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-04-26

  • Closed date

    2013-04-26

  • Last modified date

    2013-04-26

  • APAR is sysrouted FROM one or more of the following:

    LI77178

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CS FOR LINUX

  • Fixed component ID

    5724I3300

Applicable component levels

  • R623 PSY

       