LI77222: DOCUMENTATION NEEDS TO BE UPDATED TO REFLECT AUTOCOMMIT BEHAVIOR FOR STORED PROCEDURE CALLS IN CAST IRON

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as documentation error.

Error description

  • Currently the Cast Iron Information Center does not talk about
    the fact that autocommit=true cannot be set for a stored
    procedure call.
    The Cast Iron design does not allow this. In order to get around
    this a commit statement would be needed in the stored procedure.
    

Local fix

Problem summary

  • Currently the WebSphere Cast Iron Information Center does not
    talk about the fact that autocommit=true cannot be set for a
    stored procedure call.
    The Cast Iron design does not allow this. In order to get around
    this a commit statement would be needed in the stored procedure.
    
    Cast Iron explicitly sets AutoCommit = false before performing
    any transaction and then calls commit or rollback depending upon
    the result of execution.
    
    The WebSphere Cast Iron Infocenter will be updated to detail
    this limitation.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    LI77222

  • Reported component name

    WCI HV DEV ENTP

  • Reported component ID

    5725C1201

  • Reported release

    600

  • Status

    CLOSED DOC

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-02-20

  • Closed date

    2013-03-20

  • Last modified date

    2013-03-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels



Rate this page:

(0 users)Average rating

Document information


More support for:

WebSphere Cast Iron Hypervisor Edition Enterprise

Software version:

6.0.0

Reference #:

LI77222

Modified date:

2013-03-20

Translate my page

Machine Translation

Content navigation