APAR status
Closed as program error.
Error description
The following exception is seen when an attempt is made to open a project on Studio V6.3, when the original project was created on a previous version of Cast Iron Error opening project. Message: java.lang.ClassCastException: com.approuter.studio.configprops.ConfigurationProperty incompatible with java.lang.String Level: SEVERE This occurs when the original project that was developed uses Configuration Properties in the HTTP connector activity.
Local fix
Open the project in pre v6.3 Studio and remove configuration properties for all HTTP connector activities (where ever used).Provide direct values instead of using configuration properties.
Problem summary
WebSphere Cast Iron Studio projects having configuration properties used in HTTP connector activities fail to open in V6.3 of Studio. The user is presented with the following error message: Error opening project: java.lang.ClassCastException: com.approuter.studio.configprops.ConfigurationProperty incompatible with java.lang.String Level: SEVERE This occurs when the original project that was developed uses Configuration Properties in the HTTP connector activity.
Problem conclusion
The issue is now fixed and is targeted for WebSphere Cast Iron fixpack 6.3.0.1 Announcements of new fix packs are made on the WebSphere Cast Iron Support Portal at http://www-947.ibm.com/support/entry/portal/Overview/Software/We bSphere/WebSphere_Cast_Iron_Cloud_integration For planned fixpack maintenance release dates, see the following support announcement: http://www-01.ibm.com/support/docview.wss?uid=swg27036374
Temporary fix
Comments
APAR Information
APAR number
LI77179
Reported component name
WS CASTIRON HV
Reported component ID
5725C1200
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt
Submitted date
2012-12-19
Closed date
2012-12-21
Last modified date
2013-01-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WS CASTIRON HV
Fixed component ID
5725C1200
Applicable component levels
R630 PSY
UP
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.