APAR status
Closed as program error.
Error description
If a variable that is used by any of the Data Quality activities is renamed, it selects another variable after renaming. Steps to reproduce scenario: 1. Drop a merge activity in an orchestration and configure the activity by selecting variables 2. Select an activity other than the configured merge activity to rename the variables used by it. 3. Go to variable tab. 4. Change the variable names of those which are used in the merge activity. 5. Check the configure panel of the merge activity and the variable initially selected has changed and another variable is shown selected. The issue is reproducible with all the Data Quality activities.
Local fix
While rename the variable within a activity, don't select other activity during the operation.
Problem summary
When a variable is renamed in the variable panel in any of the Data Quality activities (i.e: Filter and Profile, Lookup, Sort or Merge), that variable will not get renamed correctly, and the drop down list containing the variable will have wrong selection.
Problem conclusion
The problem is fixed by adding a listener to the Data Quality activities which listens for variable renaming events, so that when a variable is renamed, any Data Quality activity which uses that variable will get refreshed. The fixed is targeted for WebSphere Cast Iron fix packs 6.1.0.15 and 6.3.0.1 Announcements of new fix packs are made on the WebSphere Cast Iron Support Portal at http://www.ibm.com/support/entry/portal/Overview/Software/WebSph ere/WebSphere_Cast_Iron_Cloud_integration Fix pack schedules are available here: http://www-01.ibm.com/support/docview.wss?uid=swg27036374
Temporary fix
Comments
APAR Information
APAR number
LI77126
Reported component name
WS CASTIRON HV
Reported component ID
5725C1100
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-12-04
Closed date
2012-12-21
Last modified date
2012-12-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WS CASTIRON HV
Fixed component ID
5725C1100
Applicable component levels
R610 PSY
UP
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.