IBM Support

JR56114: STALE TASK INFORMATION IS SAVED WHEN A TASK WITHOUT AUTOFLOW MODIFIED ITS OWN STATE AND COMPLETES

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A task can change its own task subject by using JavaScript.
    However, when autoflow is not enabled for that task or the task
    is the last one before the business process definition (BPD)
    flow completes, the updated subject value is not persisted in
    the database.
    

Local fix

Problem summary

  • When autoflow is not used, the business process definition (BPD)
    engine does not consider changes to its own task context that
    its own services make. The task context is loaded only once, in
    the beginning of the navigation, and is then held until the
    navigation finishes. As a result, stale task information is
    written to the database, which causes numerous other problems.
    This issue is very similar to the issue handled with interim fix
    JR55686, in which autoflow is enabled.
    

Problem conclusion

  • A fix is available for IBM BPM V8.0.1.3 that causes IBM BPM to
    refresh the task context when autoflow is disabled before saving
    the final task state in the database to make sure that the
    latest changes are considered.
    
    On Fix Central (http://www.ibm.com/support/fixcentral), search
    for JR56114:
    
    1. Select IBM Business Process Manager with your edition from
      the product selector, the installed version to the fix pack
      level, and your platform, and then click Continue.
    
    2. Select APAR or SPR, enter JR56114, and click Continue.
    
    When you download fix packages, ensure that you also download
    the readme file for each fix. Review each readme file for
    additional installation instructions and information about the
    fix.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR56114

  • Reported component name

    BPM ADVANCED

  • Reported component ID

    5725C9400

  • Reported release

    801

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-06-20

  • Closed date

    2016-09-02

  • Last modified date

    2016-09-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    BPM STANDARD

  • Fixed component ID

    5725C9500

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSFTDH","label":"IBM Business Process Manager Standard"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.1","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
04 September 2023