IBM Support

JR54948: TW.SYSTEM.MODEL.FINDPROCESS INCORRECTLY USES THE TIP SNAPSHOT CONTEXT ON PROCESS SERVER

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as fixed if next.

Error description

  • tw.system.model.findProcess incorrectly uses the TIP snapshot
    context on Process Server. This would be the expected behavior
    on Process Center but for process server it should use the
    default snapshot's context.
    
    If you then use methods like startNew it can create an instance
    in the wrong snapshot context. The instances will show up as the
    TIP snapshot in the Process Inspector.
    

Local fix

  • Use the findProcessByName method of a TWProcessAppSnapshot
    object to lookup the BPD.
    

Problem summary

  • ERROR DESCRIPTION -
    Using the Javascript API TWProcess.startNew() will create a
    process instance with the flag TIP set to ?T? in the database.
    
    
    PRODUCTS AFFECTED
    IBM Business Process Manager (BPM) Advanced
    IBM BPM Standard
    IBM BPM Express
    
    LOCAL FIX -
    None
    
    
    PROBLEM SUMMARY
    The following is an example of the effected Javascript API:
    tw.system.model.findProcess("25.31bde955-a01a-41e7-9f44-f4ce9e99
    0426","2066.be55f902-d944-40b0-a264-94fb6b15cade").startNew(null
    );
    
    The instances created will have the TIP flag set to ?T?(true)
    even when the BPD context used to start the instance is from a
    named snapshot.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    JR54948

  • Reported component name

    BPM ADVANCED

  • Reported component ID

    5725C9400

  • Reported release

    856

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-12-09

  • Closed date

    2016-02-01

  • Last modified date

    2016-02-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSFTN5","label":"IBM Business Process Manager Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"856","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: