IBM Support

JR53421: CIRCULAR GROUP MEMBERSHIPS PREVENT GROUP MEMBERSHIP SYNCHRONIZATION FROM COMPLETING

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When you use the syncGroupMembershipForAllGroups command or
    syncGroupMembershipForGroups command to update your group
    memberships, the synchronization does not complete or fails with
    a StackOverflowError.
    
    This issue occurs when one of your user repositories contains
    circular group memberships that are not identified and handled.
    The circular reference is processed until the exception occurs
    or the command is canceled.
    

Local fix

Problem summary

  • No additional information is available.
    

Problem conclusion

  • A fix is/will be available for IBM BPM V8.0.1.3, that enables
    IBM BPM to detect circular group memberships in user repository
    groups.  With the fix applied, the groups that have circular
    group memberships are logged into the SystemOut.log file. Also,
    the tracing is optimized to catch important data without
    negatively affecting performance.
    
    On Fix Central (http://www.ibm.com/support/fixcentral), search
    for JR53421:
    
    1. Select IBM Business Process Manager with your edition from
      the product selector, the installed version to the fix pack
      level, and your platform, and then click Continue.
    
    2. Select APAR or SPR, enter JR53421, and click Continue.
    
    When you download fix packages, ensure that you also download
    the readme file for each fix. Review each readme file for
    additional installation instructions and information about the
    fix.
    

Temporary fix

  • Not applicable
    

Comments

APAR Information

  • APAR number

    JR53421

  • Reported component name

    BPM ADVANCED

  • Reported component ID

    5725C9400

  • Reported release

    801

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-05-21

  • Closed date

    2015-07-22

  • Last modified date

    2015-12-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    BPM STANDARD

  • Fixed component ID

    5725C9500

Applicable component levels

  • R801 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSFTDH","label":"IBM Business Process Manager Standard"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.1","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: