Error description

  • In IBM Business Process Manager (BPM), you can  assign a task
    automatically to a particular user and open the user interface
    for that task automatically by using the auto-flow feature.
    However, when you switch the configuration parameter
    "enable-start-bpd-from-uca" to "true", which is set to "false"
    by default in 99Local.xml, the auto-flow feature no longer works
    for the first task in a business process definition (BPD). For
    tasks other than the first one, the auto-flow feature is not
    affected by the "enable-start-bpd-from-uca" parameter.
    You can verify that the malfunction in the auto-flow feature is
    really caused by this error. For this, set the
    "enable-start-bpd-from-uca" parameter temporarily to  false  and
    check whether after server restart the auto-flow feature works
    as expected. If not, you might want to double-check the BPD
    details instead.
    

Local fix

Problem summary

  • This issue occurs because a thread switch inside the workflow
    engine disables the auto-flow feature when the
    "enable-start-bpd-from-uca"parameter is set to ?true?.
    
    A fix that changes the workflow engine to separate the start
    BPD, the UCA functionality, and the auto-flow feature will be
    incorporated into a later release.
    

Problem conclusion

Temporary fix

  • Not applicable
    

Comments

APAR Information

  • APAR number

    JR50842

  • Reported component name

    BPM ADVANCED

  • Reported component ID

    5725C9400

  • Reported release

    751

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-07-21

  • Closed date

    2014-09-18

  • Last modified date

    2014-09-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    BPM STANDARD

  • Fixed component ID

    5725C9500

Applicable component levels

  • R751 PSN

       UP