APAR status
Closed as program error.
Error description
When you create a unidirectional Q subscription with a noncondensed CCD table as the target, the ASNCLP program uses the first subscribed column as a key column for replication, even if the column data type is XML. XML columns are not allowed as replication keys.
Local fix
Problem summary
If the problem occurs, change the properties of the Q subscription to remove the XML column from the replication key and then start the Q subscription. This fix prevents XML columns from being used as key columns for CCD targets.
Problem conclusion
The ASNCLP program no longer uses XML columns in replication key.
Temporary fix
Comments
APAR Information
APAR number
JR49974
Reported component name
WS Q-REPLIC LUW
Reported component ID
5724N9801
Reported release
970
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-04-14
Closed date
2014-04-14
Last modified date
2014-04-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WS Q-REPLIC LUW
Fixed component ID
5724N9801
Applicable component levels
R970 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSDP5R","label":"InfoSphere Replication Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.7","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
14 April 2014