IBM Support

JR48988: SYSTEM TOOLKIT FIX IS NOT UPDATED IN THE REPOSITORY

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Running the BPMUpdateSystemApp command in the IFixUtility tool
    does not update the IBM BPM system toolkits in the repository.
    

Local fix

  • To apply interim fixes to system toolkits, complete the
    following steps where System Data is an example:
    
    1. Change the database setting to allow the system toolkit to be
    updated:
    UPDATE <schema-id>.LSW_PROJECT LSW_PROJECT
              SET IS_IMMUTABLE = 'F'
              WHERE LSW_PROJECT.SHORT_NAME = 'TWSYS'
    
    2. Open Process Designer. If Process Designer is already open,
    close it and re-open it.
    
    3. Open the toolkit, which is the System Data toolkit in this
    example, in Process Designer.
    
    4. In the Toolkit Setting field, make a change and save it.
    
    5. Apply all system toolkit interim fixes by following the
    instructions in BPMUpdateSystemApp command.
    
    >>Make BPMUpdateSystemApp command link to
    http://pic.dhe.ibm.com/infocenter/dmndhelp/v8r5m0/index.jsp?topi
    c=%2Fcom.ibm.wbpm.ref.doc%2Ftopics%2Frref_bpmupdatesystemapp.htm
    l.
    
    6. Change the database setting to prevent the system toolkit
    from being updated:
    UPDATE <schema-id>.LSW_PROJECT LSW_PROJECT
              SET IS_IMMUTABLE = 'T'
              WHERE LSW_PROJECT.SHORT_NAME = 'TWSYS'
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  IBM BPM V8.5.0.1 Advanced, Standard, and    *
    *                  Express                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: The interim fix does not update the     *
    *                      artifacts of the system toolkits in     *
    *                      the repository.                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    An interim fix that should update IBM BPM system toolkits in
    the repository is unsuccessful.
    

Problem conclusion

  • If you apply the following fix, the IFixUtility tool will be
    fixed to ensure system toolkits are updated successfully in
    the repository.
    
    To get the fix, go to Fix Central
    (http://www.ibm.com/support/fixcentral) and search for JR48988:
    
    1. Select the product group, product, installed version, and
    platform, click Continue.
    2. Select APAR or SPR, enter JR48988, and click Continue.
    
    When downloading fix packages, ensure that you also download
    the readme file for each fix. Review each readme file for
    additional installation instructions and information about the
    fix.
    

Temporary fix

  • Yes.
    To apply interim fixes to system toolkits, complete the
    following steps where System Data is an example:
    1. Change the database setting to allow the system toolkit to
    be updated:
        UPDATE <schema-id>.LSW_PROJECT LSW_PROJECT
    SET IS_IMMUTABLE = 'F'
    WHERE LSW_PROJECT.SHORT_NAME = 'TWSYS'
    2. Open Process Designer. If Process Designer is already open,
    close it and re-open it.
    3. Open the toolkit, which is the System Data toolkit in this
    example, in Process Designer.
    4. In the Toolkit Setting field, make a change and save it.
    5. Apply all system toolkit interim fixes by following the
    instructions in BPMUpdateSystemApp command.
    6. Change the database setting to prevent the system toolkit
    from being updated:
    UPDATE <schema-id>.LSW_PROJECT LSW_PROJECT
    SET IS_IMMUTABLE = 'T'
    WHERE LSW_PROJECT.SHORT_NAME = 'TWSYS'
    

Comments

APAR Information

  • APAR number

    JR48988

  • Reported component name

    BPM ADVANCED

  • Reported component ID

    5725C9400

  • Reported release

    850

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-01-08

  • Closed date

    2014-01-27

  • Last modified date

    2014-01-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    BPM ADVANCED

  • Fixed component ID

    5725C9400

Applicable component levels

  • R800 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSFTN5","label":"IBM Business Process Manager Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
11 October 2021