JR46507: WHEN CALLING AN ADVANCED INTEGRATION SERVICE (AIS) WITH DATETIME VARIABLE, THE MILLISECONDS ARE LOST.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When calling an Advanced Integration Service (AIS) with datetime
    attribute, the milliseconds are gone when reaching the client.
    The Client receives the datetime variable without milliseconds.
    The milliseconds are set to "000".
    The same behavior occurs also backwards, when sending a
    datetime field from any module with SCA binding to the process
    application, the milliseconds are omitted, too.
    

Local fix

  • n/a
    

Problem summary

  • For requests and responses sent to and received from
    advanced integration services (AIS), dateTime and time values
    are loosing their millisecond part. This interim fix enables
    to preserve the millisecond part.
    

Problem conclusion

  • To enable preserving the milliseconds for requests and reponses
    to and from AIS, add the following to your 100Custom.xml
    configuration file and restart the servers:
    <properties>
      <server>
        ...
    
    <preserve-milliseconds-for-ais>true</preserve-milliseconds-for-a
    is>
        ...
      </server>
    </properties>
    
    Problem will be fixed with V8501
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR46507

  • Reported component name

    BPM ADVANCED

  • Reported component ID

    5725C9400

  • Reported release

    850

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-04-30

  • Closed date

    2013-08-14

  • Last modified date

    2013-08-14

  • APAR is sysrouted FROM one or more of the following:

    JR46491

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    BPM ADVANCED

  • Fixed component ID

    5725C9400

Applicable component levels

  • R850 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSFTN5","label":"IBM Business Process Manager Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
08 January 2022