IBM Support

JR45342: Q APPLY MAY NOT PUT MONITOR ROWS TO THE APPLYMON TABLE DUE TO A COUNTER MISMATCH.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Q APPLY may not put monitor rows to the APPLYMON table due to a
    counter mismatch. ASN7620W with "The program could not gather
    monitoring information for "???" apply or spill agents for
    receive queue <queue_name>. The program will report this
    information after the next monitor interval." may be seen.
    

Local fix

Problem summary

  •  Q APPLY reports ASN7620W in the log but never
    recovers and no monitor rows are published.
    Only a restart of Q APPLY fixes the issue.
    

Problem conclusion

  •  The internal space for the counters has been
    increased to avoid possible issues when
    getting close to the old maximum number
    allowed.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR45342

  • Reported component name

    WS Q-REPLIC LUW

  • Reported component ID

    5724N9801

  • Reported release

    A13

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-01-09

  • Closed date

    2013-01-09

  • Last modified date

    2013-01-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WS Q-REPLIC LUW

  • Fixed component ID

    5724N9801

Applicable component levels

  • RA13 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSDP5R","label":"InfoSphere Replication Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A13","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]