Skip to main content

JR44815: A CCD FAN-OUT SETUP CAN HAVE DATA LOSS WHEN THE CCD REGISTER TBL SYNCHPOINT IS UPDATED INCORRECTLY WHEN QAPPLY RESTARTS


Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • In A CCD fan-out setup data loss might occur because SYNCHPOINT
    value in REGISTER table for CCD was updated incorrectly when
    Q Apply was restarted.
    

Local fix

Problem summary

  •  Q Apply saved incorrect value of MAX commitseq
    from the CCD when Q Apply is restarted and resulted in the
    wrong initial value in register table.
    

Problem conclusion

  •  Correct Q Apply logic so that the correct
    value of MAX commitseq is retrieved.
    .
    A fix for this problem will be available in DB2 LUW V9.7 FP8
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR44815

  • Reported component name

    WS Q-REPLIC LUW

  • Reported component ID

    5724N9801

  • Reported release

    970

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-11-16

  • Closed date

    2012-11-16

  • Last modified date

    2012-11-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WS Q-REPLIC LUW

  • Fixed component ID

    5724N9801

Applicable component levels

  • R970 PSY

       UP

Rate this page:

(0 users)Average rating

Copyright and trademark information

IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.

Rate this page:


(0 users)Average rating

Add comments

Document information

InfoSphere Replication Server


Software version:
9.7


Reference #:
JR44815


Modified date:
2012-11-16

Translate my page

Content navigation