JR44218: SCA HTTP BINDING READ TIMEOUT NOT SET PROPERLY.

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Using the Admin Console to update a SCA module's http binding
    read timeout for one method may alter the read timeout for a
    different method in the module. As a result the read timeout
    value has been set incorrectly and unexpected timeouts may
    occur.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  WebSphere Process Server Version 7003       *
    ****************************************************************
    * PROBLEM DESCRIPTION: SCA HTTP binding read timeout not set   *
    *                      propertly                               *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Using the Admin Console to update a SCA module's http binding
    read timeout for one method may alter the read timeout for a
    different method in the module. As a result the read timeout
    value has been set incorrectly and unexpected timeouts may
    occur.
    

Problem conclusion

  • The ifix is used to make sure the read time out set correctly,
    Install/Dependency information is available in the readme.txt
    on FixCentral. When the user goes to the download files page
    in FixCentral, the readme will be available with the fix
    package as a separate download.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR44218

  • Reported component name

    WEB PROC SERVER

  • Reported component ID

    5724L0100

  • Reported release

    700

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-09-26

  • Closed date

    2012-12-20

  • Last modified date

    2012-12-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEB PROC SERVER

  • Fixed component ID

    5724L0100

Applicable component levels

  • R700 PSY

       UP



Rate this page:

(0 users)Average rating

Add comments

Document information


More support for:

WebSphere Process Server

Software version:

7.0

Reference #:

JR44218

Modified date:

2012-12-20

Translate my page

Machine Translation

Content navigation