IBM Support

JR40096: ERROR "RUN TIME ERROR 457 THIS KEY IS ALREADY ASSOCIATED WITH AN ELEMENT OF THIS COLLECTION" WHEN SWITCHING BACK TO DS 7.5

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Customer has 2 versions of datastage client in his machine
    (7.5.3 & 7.5)
    He uses Multi-Client Manager to move from one to second it's
    work correct and then when he try to use the designer of
    director icons of 7.5 he receive error "Run time error 457 this
    key is already associated with an element of this collection"
    
    This Technote may apply:
    
    https://www-304.ibm.com/support/docview.wss?uid=swg1JR37392
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    Users of Multi Client Manager
    ****************************************************************
    PROBLEM DESCRIPTION:
    When switching DataStage Clients using Multi-Client Manager
    (MCM), sometimes the client set would throw a runtime error
    (457) during the Attach dialog.
    ****************************************************************
    RECOMMENDATION:
    Apply patch JR40096
    ****************************************************************
    

Problem conclusion

  • The problem is due to changes in the encryption routine for
    passwords where details are longer than 32 characters.
    
    This is actually a problem in the Attach dialog, not MCM, or the
    switching process.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR40096

  • Reported component name

    WIS DATASTAGE

  • Reported component ID

    5724Q36DS

  • Reported release

    801

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-07-15

  • Closed date

    2011-08-17

  • Last modified date

    2011-08-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WIS DATASTAGE

  • Fixed component ID

    5724Q36DS

Applicable component levels

  • R750 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"IBM InfoSphere DataStage"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: