APAR status
Closed as program error.
Error description
Error Message: N/A . Stack Trace: N/A . N/A
Local fix
N/A
Problem summary
When user tries to set the system properties like os.name or os.version or os.arch property values from command line, those values are ignored and those properties are always set to default values during runtime.
Problem conclusion
This defect will be fixed in: 5.0.0 SR12 6.0.0 SR7 . Observed that these properties are not set with writable flags and this made the retention of default values. . To obtain the fix: Install build 20091202 or later
Temporary fix
Comments
APAR Information
APAR number
IZ65532
Reported component name
J9 COMMON CODE
Reported component ID
620700127
Reported release
600
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-11-24
Closed date
2009-12-14
Last modified date
2009-12-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
J9 COMMON CODE
Fixed component ID
620700127
Applicable component levels
R600 PSN