APAR status
Closed as program error.
Error description
Long running application process failed with a MVS abend code E37-04 while an enqueue was held on a shared PDS member. The application did not allow process to exit via RTM. When the same application process attempted to access the same PDS member later it could not because the enqueue was still in place.
Local fix
None. Stopping the application and restarting it to free any enqueues JRIO is still holding on behalf of the application.
Problem summary
Long running application process failed with a MVS abend code E37-04 while an enqueue was held on a shared PDS member. The application did not allow process to exit via RTM. When the same application process attempted to access the same PDS member later it could not because the enqueue was still in place.
Problem conclusion
This defect will be fixed in: 6.0.0 SR6 . An LE condition handler installed to catch the abend and return control to JRIO so the resource enqueue could be released. This defect will be fixed in: 6.0 SR 6 Fixed with Hursley defect 153532 To obtain the fix: Install build 20090726 or later . To obtain the fix: Install build 20090728 or later
Temporary fix
None. Stopping the application and restarting it to free any enqueues JRIO is still holding on behalf of the application ZE FIX ERROR PM28442 11/01/18
Comments
APAR Information
APAR number
IZ55460
Reported component name
SECURITY
Reported component ID
620700125
Reported release
600
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-07-16
Closed date
2009-07-27
Last modified date
2011-01-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SECURITY
Fixed component ID
620700125
Applicable component levels
R600 PSN
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSNVBF","label":"Runtimes for Java Technology"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0","Edition":"","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]
Document Information
Modified date:
07 December 2020