Skip to main content

IY83108: IFT SETSOCKOPT FAILED ERRNO 13


Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as documentation error.

Error description

  • According to documentation:
    .
    - The Analyzer user ID must have super (root) user authority.
    - The Collector user ID must have sufficient permissions and
    disk space
    to write log files to the PathWAI Web Response Monitor
    filesystem and to
    delete old log files.
    - The Manager Client user ID must have sufficient permissions
    and disk
    space to read the log files from the PathWAI Web Response
    Monitor
    filesystem.
    - The Manager Server user ID must have sufficient permissions
    and disk
    space to write log files to the PathWAI Web Response Monitor
    filesystem.
    .
    This is not correct, since the collector need the root account,
    because its setsockopt() routine need such permission. Both
    analyzer and collector need super permission.
    .
    The Manager Server and client can be launched by other user as
    document
    said.
    

Local fix

Problem summary

  • WRM collector should be started by root account. This is not
    described in userguide.
    

Problem conclusion

  • Since WRM have no new release, we will create technotes instead.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IY83108

  • Reported component name

    WEB RESPNSE MON

  • Reported component ID

    5724K5900

  • Reported release

    110

  • Status

    CLOSED DOC

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-03-23

  • Closed date

    2006-04-21

  • Last modified date

    2006-04-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

Rate this page:

(0 users)Average rating

Copyright and trademark information

IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.

Rate this page:


(0 users)Average rating

Add comments

Document information

Tivoli Web Response Monitor


Software version:
110


Reference #:
IY83108


Modified date:
2006-04-21

Translate my page

Content navigation