APAR status
Closed as fixed if next.
Error description
After upgrade from CI 12.1.1 to 12.1.4 find that In Cad Integrator for Microstation cannot do a Sync Full command successfully if there are more than 14 people assigned to any space. You will be kicked out of Microstation or get a message indicating that MicroStation has stopped working and be forced to Close the progra.
Local fix
No
Problem summary
The issue happens when there is a label applied that is very long, for example the 'People' label style appends every person to the label string. If the string is 'too long', i.e. more than 256 characters, it overflows the a char buffer on the heap, causing stack corruption, usually causing MicroStation to crash immediately.
Problem conclusion
Resolve an issue in MicroStation where long label style results generated as a result of full sync, for example full sync with the "People" label style where a space has a large number of people in it, could cause MicroStation to crash. This is targeted to the 1h2017 Cad Integrator release
Temporary fix
Comments
APAR Information
APAR number
IV92514
Reported component name
TRI CAD INTEG/P
Reported component ID
5725F45CI
Reported release
C11
Status
CLOSED FIN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-01-23
Closed date
2017-01-27
Last modified date
2017-01-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
999
Fix information
Applicable component levels
RC15 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSHEB3","label":"IBM TRIRIGA Application Platform"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C11","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
09 August 2022