APAR status
Closed as program error.
Error description
Error Message: N/A . Stack Trace: N/A . A user specified CRL distribution timeout appears to be ignored by the IBM Java CertPath component. This timeout value is specified via the Java sysem property -Dcom.ibm.security.crls.timeout=xx where "xx" is specified in seconds.
Local fix
Problem summary
A user specified CRL distribution timeout appears to be ignored by the IBM Java CertPath component. This timeout value is specified via the Java sysem property -Dcom.ibm.security.crls.timeout=xx where "xx" is specified in seconds.
Problem conclusion
The CertPath component was performing an operation over the connection with the distribution point "before" applying the timeout to the connection. Therefore, if the distribution point was unreachable, a default timeout value of 20 seconds or more would be experienced by the caller. The CertPath code has been modified to apply the user specified timeout value to the connection immediately after the connection is created. . This APAR will be fixed in the following Java Releases: 8 SR3 FP21 (8.0.3.21) 7 R1 SR4 (7.1.4.0) 7 SR10 (7.0.10.0) . Contact your IBM Product's Service Team for these Service Refreshes and Fix Packs. For those running stand-alone, information about the available Service Refreshes and Fix Packs can be found at: https://www.ibm.com/developerworks/java/jdk/
Temporary fix
Comments
APAR Information
APAR number
IV90912
Reported component name
SECURITY
Reported component ID
620700125
Reported release
270
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-11-18
Closed date
2016-11-18
Last modified date
2016-11-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SECURITY
Fixed component ID
620700125
Applicable component levels
R270 PSY
UP
R260 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSNVBF","label":"Runtimes for Java Technology"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"270","Edition":"","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]