IBM Support

IV77647: TRIRIGA 3413-PROBLEMS WITH OMING SECURITY GROUPS FOR READ ONLY ACCESS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as fixed if next.

Error description

  • PROBLEM:
    
    Tririga 3413-Problems with OMing security groups for read only
    access
    
    ENVIRONMENT:
    
    - Tririga Platform version 3.4.1.3 LA002
    - Tririga Application version 10.3 customised
    - Operating System. Windows 2008 64bit
    - Application Server version WebSphere Application Server
    8.5.5.1
    - Database version. 12c
    
    STEPS:
    
    When a security group is OM'd into the platform 3.4.1.3, the
    process changes any read access to inherit.
    The service_id in the app_object_permission table is changed
    from 10(for read access) to 204 (which is used for report
    manager) during the OM process.
    The platform therefore interprets this as inherit access.
    

Local fix

  • n/a
    

Problem summary

  • The issue is because of Service label of "Read" with different
    service_id (10 & 204). When getting the service Id based on
    name in destination enviornment, it was getting the service_id
    of 204 for "Read" access. Changed the label to "Read -
    MyReport" for service Id 204.
    

Problem conclusion

  • Fixed an issue where read only access in a group getting
    changed to inherit from parent after group is imported. This is
    targeted to the 2H2015 release, as well as targeted to the
    3.4.2.2 fix pack, and targeted to the 3.4.1.2 fix pack if it
    becomes available.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV77647

  • Reported component name

    TRI APP PLTFM R

  • Reported component ID

    5725F26RE

  • Reported release

    341

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-10-05

  • Closed date

    2015-10-08

  • Last modified date

    2015-10-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • 999
    

Fix information

Applicable component levels

  • R342 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSHEB3","label":"IBM TRIRIGA Application Platform"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"341","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
30 March 2022