APAR status
Closed as program error.
Error description
Error Message: When using direct input and output ByteBuffer to perform encryption/decryption, the actual amount of encrypted/decrypted data returned is not the same as the expected amount. . Stack Trace: N/A .
Local fix
Problem summary
Last block of data is not processed when using DIRECT ByteBuffer and ByteBuffer.remaining is 0 when calling Cipher.doFinal()
Problem conclusion
The fix is to process the buffered data even if ByteBuffer.remaining is 0 when calling Cipher.doFinal() The associated RTC PR is 96113 The associated Austin CMVC defect is 116806 The associated Hursley CMVC defect is 202845 The associated APAR is IV74909 JVMs affected : Java 5.0, Java 6.0, Java 6.1, Java 7.0, Java 7.1 and Java 8.0 The fix was delivered for Java 5.0 SR16 FP14, Java 6.0 SR16 FP15, Java 6.1 SR8 FP15, Java 7.0 SR9 FP20, Java 7.1 SR3 FP20 and Java 8.0 SR2 The affected jar is "ibmjcefw.jar". The build level of this jar for the affected releases is "20150722" . This APAR will be fixed in the following Java Releases: 7 R1 SR3 FP20 (7.1.3.20) 6 SR16 FP15 (6.0.16.15) 8 SR2 (8.0.2.0) 5.0 SR16 FP14 (5.0.16.14) 6 R1 SR8 FP15 (6.1.8.15) 7 SR9 FP20 (7.0.9.20) . Contact your IBM Product's Service Team for these Service Refreshes and Fix Packs. For those running stand-alone, information about the available Service Refreshes and Fix Packs can be found at: https://www.ibm.com/developerworks/java/jdk/
Temporary fix
Comments
APAR Information
APAR number
IV75773
Reported component name
JAVA 5 SECURITY
Reported component ID
620500125
Reported release
500
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-08-04
Closed date
2015-08-04
Last modified date
2015-08-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
JAVA 5 SECURITY
Fixed component ID
620500125
Applicable component levels
R500 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSNVBF","label":"Runtimes for Java Technology"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.0","Edition":"","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]