APAR status
Closed as program error.
Error description
Error Message: N/A . Stack Trace: N/A . Because the last page used in the debug data area is not memory protected as read-only by the JVM, there is a chance of this page getting corrupt, which may result in unexpected behavior including crash when any attempt is made to access the corrupt data in the page.
Local fix
N/A
Problem summary
JVM does not mark the last used page of debug data area as read-only when it determines that no more data can be added to the debug data area of the shared cache. This leaves the data in that page open to corruption which can cause unexpected behavior in the JVM accessing the corrupt data.
Problem conclusion
JVM has been updated to mark the partially filled page of debug data area as read-only once it determines that no more data can be added to the debug data area of the shared class cache. . This APAR will be fixed in the following Java Releases: 7 R1 SR3 FP10 (7.1.3.10) 8 SR1 FP10 (8.0.1.10) 6 R1 SR8 FP7 (6.1.8.7) 7 SR9 FP 10 (7.0.9.10) . Contact your IBM Product's Service Team for these Service Refreshes and Fix Packs. For those running stand-alone, information about the available Service Refreshes and Fix Packs can be found at: https://www.ibm.com/developerworks/java/jdk/
Temporary fix
Comments
APAR Information
APAR number
IV73742
Reported component name
J9 COMMON CODE
Reported component ID
620700127
Reported release
270
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-05-29
Closed date
2015-06-08
Last modified date
2015-06-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
J9 COMMON CODE
Fixed component ID
620700127
Applicable component levels
R270 PSY
UP
R260 PSY
UP