IBM Support

IV73676: JDMPVIEW 'INFO THREAD' COMMAND VERY SLOW ON DUMPS CONTAINING A L ARGE NUMBER OF THREADS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Error Message: When running the jdmpview "info thread" command
    on a core dump of the IBM JVM the command takes a long time to
    run or never terminates.
    .
    Stack Trace: N/A
    .
    

Local fix

Problem summary

  • The jdmpview "info thread" command handled JVM core dumps
    containing large numbers of threads inefficiently. If the number
    of threads was of the order of 10,000 or greater the command
    would not complete in a reasonable amount of time.
    The number of threads within the JVM can be determined from
    other diagnostic tools, for example a javacore.txt file.
    

Problem conclusion

  • The "info thread" command has been modified to perform better
    when there were many threads.
    .
    This APAR will be fixed in the following Java Releases:
       7    SR9 FP 10 (7.0.9.10)
       6 R1 SR8 FP7   (6.1.8.7)
       8    SR1 FP10  (8.0.1.10)
    .
    Contact your IBM Product's Service Team for these Service
    Refreshes and Fix Packs.
    For those running stand-alone, information about the available
    Service Refreshes and Fix Packs can be found at:
               https://www.ibm.com/developerworks/java/jdk/
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV73676

  • Reported component name

    J9 COMMON CODE

  • Reported component ID

    620700127

  • Reported release

    260

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-05-28

  • Closed date

    2015-05-28

  • Last modified date

    2015-06-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    J9 COMMON CODE

  • Fixed component ID

    620700127

Applicable component levels

  • R260 PSY

       UP

  • R270 PSY

       UP