APAR status
Closed as program error.
Error description
Error Message: The following error message is written into a javacore, at the end of the GC history section:1INTERNAL An exception occurred attempting to access in-flight data. Internal diagnostics:2INTERNAL J9Generic_Signal_Number: 000000042INTERNAL Signal_Number: 0000000BThe JVM may also issue the following or a similar message to stderr:UTE438: Unable to get formatString for j9vm.13175 - no such tracepoint - maximum allowable tracepoint for that component is 480 . Stack Trace: N/A . The javacore GC history section is complete, but with the error message at the end of the section. The remaining sections of the javacore are also complete and the JVM continues to run.
Local fix
Problem summary
The problem is caused when the JVM is processing the circular memory buffer of GC history tracepoints for output in a javacore dump.
Problem conclusion
The JVM has been updated to process the tracepoints correctly. . This APAR will be fixed in the following Java Releases: 7 SR9 (7.0.9.0) 7 R1 SR3 (7.1.3.0) 6 SR16 FP4 (6.0.16.4) 8 SR1 (8.0.1.0) 6 R1 SR8 FP4 (6.1.8.4) . Contact your IBM Product's Service Team for these Service Refreshes and Fix Packs. For those running stand-alone, information about the Service Refreshes and Fix Packs can be found at: https://www.ibm.com/developerworks/java/jdk/
Temporary fix
Comments
APAR Information
APAR number
IV71079
Reported component name
J9 COMMON CODE
Reported component ID
620700127
Reported release
260
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-03-16
Closed date
2015-03-17
Last modified date
2015-04-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
J9 COMMON CODE
Fixed component ID
620700127
Applicable component levels
R260 PSY
UP
R270 PSY
UP
R600 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSNVBF","label":"Runtimes for Java Technology"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]
Document Information
Modified date:
21 February 2022