APAR status
Closed as program error.
Error description
Error Message: N/A . Stack Trace: N/A . This problem only affects z/OS 31-bit JVMs.When running the JVM without the -XCEEHDLR option, if a SIGSEGV, SIGILL or SIGFPE occurs, only half of the contents of the FP registers are displayed in the javacore file and on the terminal.
Local fix
Use of the -XCEEHDLR option avoids this problem.
Problem summary
The problem was caused because the FP registers had been incorrectly tagged and, as a result, associated with a data type that could only accommodate half of the necessary bytes on the 31-bit platform.
Problem conclusion
The JVM has been updated and the FP registers have been properly tagged. . This APAR will be fixed in the following Java Releases: 7 R1 SR3 (7.1.3.0) 6 R1 SR8 FP4 (6.1.8.4) 5.0 SR16 FP10 (5.0.16.10) 7 SR9 (7.0.9.0) 6 SR16 FP4 (6.0.16.4) . Contact your IBM Product's Service Team for these Service Refreshes and Fix Packs. For those running stand-alone, information about the Service Refreshes and Fix Packs can be found at: https://www.ibm.com/developerworks/java/jdk/
Temporary fix
Comments
APAR Information
APAR number
IV68042
Reported component name
J9 COMMON CODE
Reported component ID
620700127
Reported release
270
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-12-17
Closed date
2014-12-19
Last modified date
2015-04-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
IV68072
Fix information
Fixed component name
J9 COMMON CODE
Fixed component ID
620700127
Applicable component levels
R270 PSY
UP
R260 PSY
UP