IBM Support

IV50344: VIRTUAL MEMORY INCREASE FOR MTTRAPD PROBE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as fixed if next.

Error description

  • Mttrapd probe version :
    
    [prawin@BLRMMRHEL probes]$ ./nco_p_mttrapd -version
    Netcool/OMNIbus MTTrapd probe - Version 7.4.0 64-bit
    (C) Copyright IBM Corp. 1994, 2012
    
    Netcool/OMNIbus Probe API Library Version 7.4.0 64-bit
    Release ID: 16.0.3
    API Release ID: 5.40.34
    Software Compile Date: Mon Jun 17 03:34:44 UTC 2013 on
    rhat5es-build1.hursley.ibm.com (Linux 2.6.18-274.17.1.el5 #1
    SMP Wed Jan 4 22:45:44 EST 2012)
    
    
    Virtual memory increases gradually for the probe version 16.
    
    with the following setting
    
    SnmpConfigChangeDetectionInterval : 1
    

Local fix

  • Default Probe setting has the following property enabled
    
    SnmpConfigChangeDetectionInterval : 1
    
    disable it and set the value to zero
    
    SnmpConfigChangeDetectionInterval : 0
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users of nco_p_mttrapd                                   *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Virtual memory increases gradually for the probe version 16. *
    *                                                              *
    * with the following setting                                   *
    *                                                              *
    * SnmpConfigChangeDetectionInterval : 1                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * User need to upgrade to nco_p_mttrapd V17.0                  *
    ****************************************************************
    

Problem conclusion

Temporary fix

  • Default Probe setting has the following property enabled
    
    SnmpConfigChangeDetectionInterval : 1
    
    disable it and set the value to zero
    
    SnmpConfigChangeDetectionInterval : 0
    

Comments

APAR Information

  • APAR number

    IV50344

  • Reported component name

    NC/OBUS MTTRAPD

  • Reported component ID

    5724P03MT

  • Reported release

    100

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-10-04

  • Closed date

    2014-03-27

  • Last modified date

    2014-03-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

  • R100 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSSHTQ","label":"Tivoli Netcool\/OMNIbus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"100","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
27 March 2014