  • Closed as documentation error.

Error description

  • ITNM-ITNCM Integration documentation issues:
    
    1. "Applying the integration tarball (Network Manager 3.9 only)"
    ----------------------------------------------------------------
    
    Documentation states:
    
    "
    
    Before you begin...
    - Ensure that all ncp processes are stopped.
    ...
    
    itnm_status: Use this command to check if all processes are
    running. If they are, this indicates that the tarball was
    installed successfully and connectivity has been established.
    
    "
    
    But after completing those steps, itnm_status reports ncp down
    because we were instructed to take it down earlier.
    
    
    2. "Installing the Tivoli Integrated Portal components"
    -------------------------------------------------------
    
    Documentation states:
    
    "
    Log on to the Network Manager Tivoli Integrated Portal server
    as the same user who installed Network Manager, for example
    icosuser.
    
    "
    
    It is extremely unlikely ITNM/TIP was installed as icosuser as
    their documentation reccomends root, and when non-root
    installation are made it is usually with a netcool user.
    
    I also suspect that documentation should have the ITNM/TIP user
    perform ". /opt/IBM/tivoli/netcool/env.sh" so that the installer
    can provide default values for NCHOME and TIPHOME environment
    variable.
    
    
    3. "Installing the Tivoli Integrated Portal components"
    -------------------------------------------------------
    
    Documentation states:
    
    "
    
    Enter a complete path for the installation folder location, or
    accept the default.
    Note: The default directory path is /opt/IBM/tivoli/netcool/ncm
    
    "
    Above will not work on a single-server installation where a
    non-root user was used to install ITNM. The non-root user will
    not have permissions to write into the
    /opt/IBM/tivoli/netcool/ncm directory.
    
    For this I expect the documentation needs to state a suitable
    directory for single-server installation.
    
    
    4. "Installing the customized rules for Netcool Configuration
    Manager"
    --------------------------------------------------------------
    
    Documentation states:
    
    "
    4
    
    a. Uncomment and edit the following statement:
    
    # include"<$NCHOME>/etc/rules/include-snmptrap/<vendor>/
    <vendor>.master.include
    
    for example
    
    include "$NC_RULES_HOME/include-snmptrap/ibm/
    ibm.master.include.lookup"
    
    "
    
    In the above it is not clear whether or not we need to uncomment
    for all <vendor>, or just the ibm vendor.
    
    Also in the first line the file to uncomment ends with
    "master.include" but the example ends with
    "master.inculde.lookup. The same discrepancy exists in 4b and
    4c.
    
    
    5. "Installing the customized rules for Netcool Configuration
    Manager"
    -------------------------------------------------------------
    
    " Run the probe. If the probe was already running, force the
    probe to re-read the rules file so that the changes can take
    effect. "
    
    No details specificed on how to run probe or force it to re-read
    rules file
    
    
    6. "Preparing for device synchronization"
    -----------------------------------------
    
    Documentation states:
    
    "
    Check that the directory on the Netcool Configuration Manager
    server is correct for these three files:
    
        $INSTALL_DIR/config/properties/ssl.client.props
        $INSTALL_DIR/config/properties/sas.client.props
        $INSTALL_DIR/config/properties/wsjaas_client.conf
    "
    
    How would one "check that the directory is correct"? Should the
    documentation really be asking to check the files exist?
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users using ITNCM 6.3.x and ITNCM 6.4.x                      *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Integration Documentation is unclear and may lead to         *
    * incorrect configuration                                      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * View the updated Integration Documentation on the Info       *
    * Center from early December 2013                              *
    ****************************************************************
    

Problem conclusion

  • Integration Documentation has been updated to provide clearer
    steps
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV48149

  • Reported component name

    N/C CONFIG MGR(

  • Reported component ID

    5724Z3100

  • Reported release

    640

  • Status

    CLOSED DOC

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-09-12

  • Closed date

    2013-11-20

  • Last modified date

    2013-11-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS7UH9","label":"Tivoli Netcool Configuration Manager"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"640","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
20 November 2013