IV45737: ASSET IS READ ONLY WHEN TRYING TO OPEN AN ATTACHMENT IN 6.2.4 WITH 6.5 CALIBRATION WHEN USER HAS ONLY READ ONLY RIGHTS.

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

APAR status

  • Closed as program error.

Error description

  • See similar APAR IV00141 for transportation.
    
    The record is trying to perform a save.
    
    1. create a new user that only has read only rights to
    Pluscasset.
    2. Add a new attachment to an asset in the cal asset app or
    wotrack
    cal. Try to open the attachment.
    you will get error Asset is read only and exception in log.
    24 Jun 2013 14:22:08:943 [ERROR] Object ASSET is read-only.
    psdi.util.MXAccessException: Object ASSET is read-only.
    at psdi.mbo.Mbo.checkSiteOrgAccessForSave(Mbo.java:6211)
    at psdi.mbo.MboSet.saveTransaction(MboSet.java:5745)
    at psdi.txn.MXTransactionImpl.saveTransaction(MXTransactionImp
    l.java:210)
    at psdi.txn.MXTransactionImpl.save(MXTransactionImpl.java:145)
    at psdi.mbo.MboSet.save(MboSet.java:5621)
    at psdi.mbo.MboSet.save(MboSet.java:5591)
    at psdi.webclient.system.beans.AppBean.save(AppBean.java:449)
    at psdi.plusc.webclient.beans.asset.PlusCAssetAppBean.save(Unk
    nown Source)
    at psdi.webclient.system.beans.AppBean.SAVE(AppBean.java:765)
    

Local fix

  • must give full access, not read only which is not allowed.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Maximo Users on Calibration 650                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * ASSET IS READ ONLY WHEN TRYING TO OPEN AN ATTACHMENT IN      *
    * 6.2.4                                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Request interim fix for the release needed                   *
    ****************************************************************
    

Problem conclusion

  • Fix has been made and user should no longer get an error.
    
    
    The fix for this APAR is contained in the following maintenance
    package:
      | release\fix pack\interim fix for Release 650 of Calibration
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV45737

  • Reported component name

    MAXIMO CALIBRAT

  • Reported component ID

    5724R57IC

  • Reported release

    650

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-07-16

  • Closed date

    2013-09-19

  • Last modified date

    2013-09-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • MAXIMO
    

Fix information

  • Fixed component name

    MAXIMO CALIBRAT

  • Fixed component ID

    5724R57IC

Applicable component levels

  • R650 PSY

       UP



Rate this page:

(0 users)Average rating

Add comments

Document information


More support for:

IBM Maximo Calibration
Calibration

Software version:

650

Reference #:

IV45737

Modified date:

2013-09-19

Translate my page

Machine Translation

Content navigation