IV39993: UPDATING RAWCAPTURE PROPERTY VIA NCO_HTTP DOES NOT WORK COMPLETELY.

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • After updating the RawCapture property via the nco_http
    function, the property is seen as updated, the cap file is
    created but the file does not begin to get written to.
    

Local fix

  • The work around is to just reference (but not actually modify)
    %RawCapture in the rules file so that it causes the code to
    check the property value every time, i.e.
    
    
    if( false ) {
     %RawCapture=1
    }
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Anyone trying to use the nco_http interface to set the       *
    * RawCapture property on a probe.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * After updating the RawCapture property via the nco_http      *
    * interface, the property gets updated, the .cap file is       *
    * created, but no data is written to file.                     *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply the maintenance package listed in the Problem          *
    * Conclusion.                                                  *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is contained in the following maintenance
    package:
         | fix pack | 7.4.0-TIV-NCOMNIbus-FP0002
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV39993

  • Reported component name

    NETCOOL/OMNIBUS

  • Reported component ID

    5724O4800

  • Reported release

    740

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-04-16

  • Closed date

    2013-04-19

  • Last modified date

    2013-04-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    NETCOOL/OMNIBUS

  • Fixed component ID

    5724O4800

Applicable component levels

  • R740 PSY

       UP



Rate this page:

(0 users)Average rating

Document information


More support for:

Tivoli Netcool/OMNIbus
Netcool/OMNIbus

Software version:

740

Reference #:

IV39993

Modified date:

2013-04-19

Translate my page

Machine Translation

Content navigation