Skip to main content

IV36533: CSR FILE REPORTING DATA OF DECOMISSIONED PROJECT


Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Environment:
    .
    TSAM 7.2.3 + Extension for VMware Additional Disk 1.0.1.2 +
    7.2.3.0-TIV-TSAM-LA0001 + 7.2.3.0-TIV-TSAM-LA0003 +
    7.2.3.0-TIV-TSAM-LA0009
    .
    The following problem occurs with accounting:
    .
    There is a project that has been decomissioned due to end
    date reached.
    .
    Despite being terminated, the project is reported in the CSR
    file with SERVHRS=24.0
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of Tivoli Service Automation Manager
    7.2.3.0
    ****************************************************************
    * PROBLEM DESCRIPTION:
    Incorrect values in CSR file from TUAM
    ****************************************************************
    * RECOMMENDATION:
    A temporary fix is provided with 7.2.3.0-TIV-TSAM-LA0016.
    
    For permanent resolution apply Tivoli Service Automation Manager
    7.2.4.1 when available.
    

Problem conclusion

  • This fix solves a problem that incorrect values (data for
    already deprovisioned servers) are shown in the CSR file from
    TUAM.
    
    The fix for this APAR is contained in the following maintenance
    packages:
    | mod level | TivSAM 7.2.4.1
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV36533

  • Reported component name

    TSAM (& INSTALL

  • Reported component ID

    5724W7800

  • Reported release

    723

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-02-11

  • Closed date

    2013-02-12

  • Last modified date

    2013-02-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TSAM (& INSTALL

  • Fixed component ID

    5724W7800

Applicable component levels

  • R724 PSY

       UP

Rate this page:

(0 users)Average rating

Copyright and trademark information

IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.

Rate this page:


(0 users)Average rating

Add comments

Document information

Tivoli Service Automation Manager


Software version:
723


Reference #:
IV36533


Modified date:
2013-02-12

Translate my page

Content navigation