APAR status
Closed as program error.
Error description
The issue happens when the CustomAppSensor runs as an extension for a standard L3 sensor for the process which listens on all IP interfaces (marked as 0.0.0.0). In CustomAppServerSensor log we can find: DEBUG os.OsUtils - Retrieving session IP:0.0.0.0 for requested IP:0.0.0.0 The correct IP which should be used is the IP used to start discovery. Using 0.0.0.0 can result in the CustomAppSensor running the commands locally on the TADDM server and not the target therefor returning incorrect results.
Local fix
N/A
Problem summary
The issue happens when the CustomAppSensor runs as an extension for a standard L3 sensor for the process which listens on all IP interfaces (marked as 0.0.0.0). In CustomAppServerSensor log we can find: DEBUG os.OsUtils - Retrieving session IP:0.0.0.0 for requested IP:0.0.0.0 The correct IP which should be used is the IP used to start discovery. Using 0.0.0.0 can result in the CustomAppSensor running the commands locally on the TADDM server and not the target thereforreturning incorrect results.
Problem conclusion
The fix for this APAR is contained in the following maintenance packages: | Fix Pack | 7.2.1-TIV-ITADDM-FP0005
Temporary fix
Comments
APAR Information
APAR number
IV36429
Reported component name
APP DEPENDENCY
Reported component ID
5724N5500
Reported release
721
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-02-07
Closed date
2013-04-05
Last modified date
2013-04-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
APP DEPENDENCY
Fixed component ID
5724N5500
Applicable component levels
R721 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSPLFC","label":"Tivoli Application Dependency Discovery Manager"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"721","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]