IBM Support

IV34170: QUEUE MANAGER ENDS AND FDC WITH PROBE ID ZT160001 IS GENERATED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • WebSphere MQ queue manager ends.  FDC is created with Probe ID
    ZT160001 reporting "Timed-out waiting for process manager to
    start".
    The FDC indicates an attempted restart of the utility manager
    process during endmqm fails.
    
    WebSphere MQ First Failure Symptom Report
    =========================================
    Probe Id          :- ZT160001
    Component         :- zusStartManager
    Major Errorcode   :- xecX_W_DAEMON_UNAVAILABLE
    Probe Description :- AMQ6125: An internal WebSphere MQ error
    has occurred.
    Comment1          :- Timed-out waiting for process manager to
    start.
    ----------------------------------------------------------------
    MQM Function Stack
    zusQueryAncillaryProcess
    zusConnectToProcessManager
    zusStartManager
    xcsFFST
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    Users may encounter this issue during endmqm if the queue
    manager process manager had previously ended due to some issue
    with the process manager (which would normally itself be
    reported via one or more FDCs). The probe ZT160001 FDC can be
    ignored.
    
    Platforms affected:
    All Distributed (iSeries, all Unix and Windows)
    ****************************************************************
    PROBLEM SUMMARY:
    The endmqm process was attempting to restart the process manager
    if connection could not be established with it. The restart
    attempt could fail, leading to the probe ZT160001 FDC.
    

Problem conclusion

  • The endmqm process should not be attempting to restart the
    process manager and it has now been stopped from doing that.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
                       v7.1
    Platform           Fix Pack 7.1.0.3
    --------           --------------------
    Windows            7.1.0.3
    AIX                7.1.0.3
    HP-UX (Itanium)    7.1.0.3
    Solaris (SPARC)    7.1.0.3
    Solaris (x86-64)   7.1.0.3
    iSeries            7.1.0.3
    Linux (x86)        7.1.0.3
    Linux (x86-64)     7.1.0.3
    Linux (zSeries)    7.1.0.3
    Linux (Power)      7.1.0.3
    
    Platform           v7.5
    --------           --------------------
    Multiplatforms     7.5.0.2
    
    The latest available maintenance can be obtained from
    'WebSphere MQ Recommended Fixes'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006037
    
    If the maintenance level is not yet available information on
    its planned availability can be found in 'WebSphere MQ
    Planned Maintenance Release Dates'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006309
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV34170

  • Reported component name

    WMQ AIX V7

  • Reported component ID

    5724H7221

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-01-08

  • Closed date

    2013-02-21

  • Last modified date

    2013-02-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WMQ AIX V7

  • Fixed component ID

    5724H7221

Applicable component levels

  • R710 PSY

       UP