IV34004: INCORRECT OUTPUT FROM SELECT CASE STATEMENT WITH MPI

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • A test program gives out incorrect output from incorrect select
    case logic flow. If adding a case clause with only a WRITE
    statement, the program flow is correct.
    

Local fix

  • -qxflag=nrce works around the issue.
    

Problem summary

  • PROBLEM DESCRIPTION: When fusing two adjacent switch
    statements, Redundant Condition Elimination misses the code
    between the two statement in some cases, causing incorrect
    output.
    
    USERS AFFECTED: user using -qhot and all implying options.
    

Problem conclusion

  • Problem is fixed. Apply recommended service.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV34004

  • Reported component name

    XL FORTRAN FOR

  • Reported component ID

    5725C7400

  • Reported release

    E10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-12-31

  • Closed date

    2013-03-05

  • Last modified date

    2013-03-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    LI77380 LI77425

Fix information

  • Fixed component name

    XL FORTRAN FOR

  • Fixed component ID

    5725C7400

Applicable component levels

  • RE10 PSY U858424

       UP C



Rate this page:

(0 users)Average rating

Add comments

Document information


More support for:

XL Fortran for AIX
Compiler

Software version:

14.1

Reference #:

IV34004

Modified date:

2013-03-13

Translate my page

Machine Translation

Content navigation