IV32050: USERS CANNOT BUILD A NEW CM BUILD POSITION IN BUILD POSITION IN MASTER (CM)

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Problem Description:
    
    Issue Building CM Build Position in Build Position Master(CM)
    User u504693(or even Maxadmin user) cannot build a new CM Build
    Position
    in Build Position
    Master(CM)
    e.g.
    Family: BR700
    Label: 711402-913040-01-001
    
    Additional comment from the client:
     We have received the following update from Rolls-Royce. Could
    you
    please update the case with it, " The value 711401-913040-01-001
    doesn't
    exist in the could-build for any series/model, so the check
    fails and
    you are then unable to proceed to associate CM Items and Zones.
    In
    principle I don't necessarily see anything wrong with this, but
    I would
    have expected that checking the Phantom Position checkbox would
    then let
    you use a label that was not in the could-build for the
    specified series
    otherwise how can Phanton positions be used? summary, I think
    there is a
    coding/logic flaw in the Maximo-SDM GUI and IBM should be asked
    to look
    at it. (Clarification already provided, but may not have made it
    to
    IBM)
    
    Version of Maximo and ACM:
    ACM 7.1.1.2
    BS 7.1.1.8
    

Local fix

  • n/a
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users of the Build Position Master (CM) application within   *
    * Asset Configuration Manager                                  *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * System prevents free text entry into the Position Code when  *
    * the Phantom Position checkbox is ticked.                     *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Deploy the interim fix to address this issue.                *
    ****************************************************************
    Phantom Positions relate to those positions which are not
    defined within any Model build hierarchy.
    

Problem conclusion

  • Code modified to allow free text Position Codes for Phantom
    Positions.
    The fix for this APAR is contained in the following maintenance
    package:
      | release\fix pack | Interim Fix for Release 7501 Asset
    Configuration Manager
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV32050

  • Reported component name

    ASSETS

  • Reported component ID

    5724R46AS

  • Reported release

    711

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-11-19

  • Closed date

    2012-12-04

  • Last modified date

    2012-12-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • MAXIMO
    

Fix information

  • Fixed component name

    ASSETS

  • Fixed component ID

    5724R46AS

Applicable component levels

  • R750 PSY

       UP



Document information


More support for:

Maximo Asset Management
Assets

Software version:

711

Reference #:

IV32050

Modified date:

2012-12-04

Translate my page

Content navigation