IV30705: CEI EVENT-EMITTING MICROFLOWS LEAVE 'ORPHAN' RECORDS IN BPEDB

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Description: When CEI common base event (CBE) emission is
    enabled on a
    BPEL process, an event counter table (PROGRESS_COUNTER_T) keeps
    track of
    the sequence of events that each process instance emits. Records
    in this
    database table should get deleted, when the associated process
    instance
    gets deleted. For microflows this does not work, i.e. an
    'orphan' record
    for each deleted microflow remains in the table.
    

Local fix

  • no local fix
    

Problem summary

  • Problem Description:
    CEI event-emitting microflows leave 'orphan' records in BPEDB.
    
    Problem Summary:
    When CEI common base event (CBE) emission is enabled on a BPEL
    process, an event counter table (PROGRESS_COUNTER_T)
    keeps track of the sequence of events that each process instance
    emits. Records in this database table should get
    deleted, when the associated process instance gets deleted. For
    microflows this does not work, i.e. an 'orphan'
    record for each deleted microflow remains in the table.
    
    Problem Conclusion:
    Progress counter records are no longer be persisted for
    microflows.
    

Problem conclusion

  • Problem fixed
    iFiy available on top V620 FP3
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV30705

  • Reported component name

    BUS PRC CHOREOG

  • Reported component ID

    5655FLW11

  • Reported release

    620

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-10-23

  • Closed date

    2012-11-26

  • Last modified date

    2012-11-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    IV30708 JR44489 JR44490 JR44491 JR44775

Fix information

  • Fixed component name

    BUS PRC CHOREOG

  • Fixed component ID

    5655FLW11

Applicable component levels

  • R620 PSY

       UP



Rate this page:

(0 users)Average rating

Add comments

Document information


More support for:

WebSphere Process Server
Business Process Choreographer

Software version:

6.2

Reference #:

IV30705

Modified date:

2012-11-26

Translate my page

Machine Translation

Content navigation