IBM Support

IV30065: CANNOT CREATE INTERFACE TABLE BECAUSE OF ALIASNAME DUPLICATES CONFLICT EXISTS FOR OBJECT STRUCTURE USER DEFINED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Customer is attempting to create an Interface table for an
    Enterprise
    Service based on a duplicated Object Structure.  Receives the
    error
    "BMXAA6131E Selection of Interface table is not allowed due to
    object structure Alias conflicts. Table and Object Structure
    pair is: TEST_MIF_CONTRACTS/TESTPC".
    
    The TESTPC Object Structure has the Alias Conflict box Checked,
    but inthe Add/Modify Alias option does not identify any
    attributes that are duplicates.
    
    
    Steps to rproduce.
    
    Select an Object Structure that have Aliasnames for duplicate
    attributes but does not have the support flat files check box
    checked. (MXPC).
    
    Duplicate this Object structure giving it a unique name (TESTPC)
    and check the Support Flat Files check box and save the new
    Object Structure
    
    Upon saving the Object Structure the Alias Conflict flag will
    be checked
    
    In the Select Action Dropdown choose the Add/Modify Alias
    option.  For each Object you will not find any fields that has
    the duplicate checkbox checked.
    
    Goto the CONTRACTAUTH object and change the Aliasname of
    CA_VENDOR back to VENDOR .
    
    Go back into the Add/Modify Alias, goto the CONTRACTAUTH object
    and change the Aliasname of of the VENDOR field back to
    CA_VENDOR and click the OKAY Button.  The Alias Conflict flag
    will be cleared for the Object Structure.
    

Local fix

  • In the Select Action Dropdown choose the Add/Modify Alias
    option.  Find an Attribute where it is part of more than Object
    of the Object structure and the Field value is not the same as
    the Aliasname value. Change the Aliasname to match the field
    value and click the Okay button.
    Go back into the Add/Modify Alias, goto the object that was
    changed and change the Aliasname of the field back to previous
    aliasname and click the OKAY Button.  The Alias Conflict flag
    will be cleared for the Object Structure.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Any user who duplicated Object Struture and check Flat File  *
    * enabled before saving                                        *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * After duplicating if user click Flat File enable he gets     *
    * alias conflict errors                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Save before enabling Flat File Enabled                       *
    ****************************************************************
    

Problem conclusion

  • Do not allow to enable Flat File till Object Structure is saved.
    The fix for this APAR is contained in the following maintenance
    package:
    	 | release\fix pack | Interim Fix for Release 7.5.0.4 Product
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV30065

  • Reported component name

    INTEGRATION

  • Reported component ID

    5724R46I1

  • Reported release

    711

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2012-10-12

  • Closed date

    2012-11-20

  • Last modified date

    2012-11-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • Maximo
    

Fix information

  • Fixed component name

    INTEGRATION

  • Fixed component ID

    5724R46I1

Applicable component levels

  • R750 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"IBM Maximo Asset Management"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"711","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
20 November 2012