APAR status
Closed as fixed if next.
Error description
There is an issue with our OM6110 adapter (Optera6110_v3). It appears to be only populating the DC cards in the database and not the AC cards. Please see the comments below: +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+- +-+-+-+- Power supply in DC_DEV is DC, in AC_DEV is AC. Looks like ITNM does not record AC power supply but it does record DC power supply. TID SLOTID TYPE NATIVEID -------------------- --------- ------------- ------------ DC_DEVONBNO03CPE1M0001 -1 SP_VCARD SP-1-3 DC_DEVONBNO03CPE1M0001 1 PSU_CARD PSU-1-1 DC_DEVONBNO03CPE1M0001 2 16XE1DS1_CARD 16XE1DS1-1-2 DC_DEVONBNO03CPE1M0001 3 2X155M_CARD 2X155M-1-3 DC_DEVONBNO03CPE1M0001 4 8XETH_CARD 8XETH-1-4 Command: TL1Message= RTRV-EQPT:DC_DEVONBNO03CPE1M0001:ALL:951699; Response: "CHASSIS-1-0::SER=\"NNTMDAV0591V\",PEC=\"NT6Q00ACE5\",CLEI=\"SOM 8D10FRB\",REL=\"03\",CTYPE=card_BackPlane,:IS,ACT" "PSU-1-1::SER=\"NNTMDAV052NK\",PEC=\"NT6Q30MAE5\",CLEI=\"SOUPABV GAA\",REL=\"01\",CTYPE=card_PSU,:IS,ACT" "16XE1DS1-1-2::SER=\"\",PEC=,CLEI=\"\",REL=\" \",CTYPE=card_TA01,:IS,ACT" "2X155M-1-3::SER=\"\",PEC=,CLEI=\"\",REL=\" \",CTYPE=card_TXC1,:IS,ACT" "8XETH-1-4::SER=\"NNTMDAV05334\",PEC=\"NT6Q13ACE5\",CLEI=\"SOUIA Z1DAA\",REL=\"03\",CTYPE=card_TP01,:IS,ACT" "P155M-1-3-1::PEC=\"NTTP04CF\",CLEI=\"WMOTCWAJAB\",SER=\"EXLGCN0 Y62313054\",:IS,ACT" TID SLOTID TYPE NATIVEID -------------------- --------- ------------- ------------ AC_DEVONEZO01CPE1M0001 -1 SP_VCARD SP-1-3 AC_DEVONEZO01CPE1M0001 2 16XE1DS1_CARD 16XE1DS1-1-2 AC_DEVONEZO01CPE1M0001 3 2X155M_CARD 2X155M-1-3 TL1Message= RTRV-EQPT:AC_DEVONEZO01CPE1M0001:ALL:951750; "CHASSIS-1-0::SER=\"NNTMDAV04M8P\",PEC=\"NT6Q00ACE5\",CLEI=\"SOM 8D10FRB\",REL=\"03\",CTYPE=card_BackPlane,:IS,ACT" "ACPSU-1-1::SER=\"NNTMDAV04MEB\",PEC=\"NT6Q31AAE5\",CLEI=\"SOUPA AYGAB\",REL=\"02\",CTYPE=card_ACPSU,:IS,ACT" "16XE1DS1-1-2::SER=\"\",PEC=,CLEI=\"\",REL=\" \",CTYPE=card_TA01,:IS,ACT" "2X155M-1-3::SER=\"\",PEC=,CLEI=\"\",REL=\" \",CTYPE=card_TXC1,:IS,ACT" "P155M-1-3-1::PEC=\"NTTP02ED\",CLEI=\"BAOUS4NGAA\",SER=\"EXLGJPE X50630364\",:IS,ACT"
Local fix
N/A
Problem summary
Error description Current OM6110 adapter does not support discovery of AC Power Supply Units Local fix None Problem summary Based on the pattern output of the RTRV-EQPT TL1 command, the current OM6110 adapter is configured to discover DC power supply units with pattern such as "PSU-1-1::....". The AC power supply unit is not discovered since its pattern is in the form of "ACPSU-1-1::..." Problem conclusion The pattern of the AC power supply unit needs to be configured as one of the recognized TL1 output patterns on the RTRV-EQPT message. Temporary fix None Comments The fix for this issue will be included in the next enhancement release for OM6110 v4, (RFE 26573). The estimated release for RFE 26573 is 2nd quarter of 2013
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
IV29741
Reported component name
NC/PRECISION TN
Reported component ID
5724O5400
Reported release
530
Status
CLOSED FIN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-10-09
Closed date
2012-10-22
Last modified date
2012-10-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
R560 PSY