Fixes are available
APAR status
Closed as program error.
Error description
The instance name for a multi-instance agent, such as the kr2 agent, changes from lower case or mixed case to upper case after upgrade.
Local fix
Problem summary
The Agent instance name is changed to upper case after upgrade on Manage Tivoli Enterprise Service (MTEMS). On Window systems, when upgrading an IBM Tivoli Monitoring multi-instance agent to 622 Fix Pack 2 or later (including 623 GA and 623 Fix Pack 1), the agent instance names are changed to upper case on Manage Tivoli Enterprise Service (MTEMS). If the customer has a new multi-instance agent which has the entry "KQZ_INSTANCE_NAME=$(INSTANCE)" in the agent K<pc>ENV file packaged with an IBM Tivoli Monitoring installer older than 623fp2, after the upgrade there are two instaces displayed on portal server, one with the original instance name, one with upper case instance name. As a result, situations that use Manage System List (MSL) do not work properly. For example, After the upgrade, the instance "MyInstance" becomes "MYINSTANCE" on MTEMS. Both "MyInstance" and "MYINSTANCE" are shown on portal.
Problem conclusion
The code was modified to keep the correct instance name case when upgrading. Further more, if the instance name was already changed to upper case by previous upgrade, the current upgrade restores the instance to the original case. The fix for this APAR is contained in the following maintenance packages: | fix pack | 6.2.3-TIV-ITM-FP0002 | release | 6.3.0-TIV-ITM
Temporary fix
Edit the file candlehome\TMAITM6\kxxcma_instance.ini, where xx is the product code. change the line Cantask=<UPPERCASED INTANCE NAME> to Cantask=<the correct instance name> and reconfig the agent
Comments
APAR Information
APAR number
IV27438
Reported component name
OMEG DIST INSTA
Reported component ID
5608A41CI
Reported release
623
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-09-04
Closed date
2012-09-14
Last modified date
2013-01-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
OMEG DIST INSTA
Fixed component ID
5608A41CI
Applicable component levels
R623 PSY
UP
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.