Error description
Error Message: N/A . Stack Trace: N/A .
Local fix
Problem summary
If the constructor for a finalizable object stores into local variable zero (where a reference to the receiver object is stored), the wrong object may be registered for finalization.
Problem conclusion
This defect will be fixed in: 7.0.0 SR1 6.0.1 SR1 6.0.0 SR11 . The JIT and VM were fixed to use the same technique used to ensure that synchronized methods unlock the correct monitor even when the receiver reference is destroyed by a store to local variable zero.