APAR status
Closed as program error.
Error description
When using WebSphere MQ internet pass-thru ( SupportPac MS81 ) Version 2.0.0.3, an ERROR 1407-0 is logged each time a client closes a connection. This issue can be reproduced as follows (all components are on the same system): amqsputc --> MQIPT (port 1407) --> QMGRName (port 1420) For example: Use the amqsputc sample program to put a single message to a queue on the queue manager. Once the sample program is ended (which effectively closes the connection), the ERROR 1407-0 is logged by MQIPT (see the MQIPT log).
Local fix
Problem summary
**************************************************************** USERS AFFECTED: Users scanning the MQIPT log for the string error, to detect failure conditions. Platforms affected: All Distributed (iSeries, all Unix and Windows) **************************************************************** PROBLEM SUMMARY: MQIPT logs a benign error when a connection is closed, no matter what the reason for the connection closure. The error logged, does not prevent MQIPT from operating correctly, but appears as a failure in the MQIPT log file.
Problem conclusion
The MQIPT code has been updated to check the reason for the connection closure, and report the closure appropriately in the log file. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Platform v7.5 -------- -------------------- Multiplatforms 7.5.0.2 The latest available maintenance can be obtained from 'WebSphere MQ Recommended Fixes' http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006037 If the maintenance level is not yet available information on its planned availability can be found in 'WebSphere MQ Planned Maintenance Release Dates' http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006309 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IV25243
Reported component name
WMQ SOL SPARC
Reported component ID
5724H7223
Reported release
701
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-07-26
Closed date
2013-01-14
Last modified date
2013-01-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WMQ SOL SPARC
Fixed component ID
5724H7223
Applicable component levels
R701 PSY
UP
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.