APAR status
Closed as documentation error.
Error description
. It looks like the documented setup for nco_proxyserv in failover using nco_pa has not been tested. . What appears to work is that in this case one needs to set PROXYP props option RemoteServer to AGG_V and not AGG73. (ie point it to the VIRTUAL PAIR not the Primary objectserver) . It also works if you stop both AGG73(primary objectserver ) and PROXYP. Regression apar = no
Local fix
. What appears to work is that in this case one needs to set PROXYP props option RemoteServer to AGG_V and not AGG73. (ie point it to the VIRTUAL PAIR not the Primary objectserver) . It also works if you stop both AGG73(primary objectserver ) and PROXYP.
Problem summary
**************************************************************** * USERS AFFECTED: * * All users of IBM Tivoli Netcool/OMNIbus V7.3.0. * **************************************************************** * PROBLEM DESCRIPTION: * * The high availability configuration using proxy servers * * described in the -Configuring proxy servers for failover- * * topic does not work when the primary proxy server is run * * under process control (nco_pa). * **************************************************************** * RECOMMENDATION: * * Publication of the revised documentation is planned for Q3 * * 2012. * * * * The revised topic will be available at: * * http://publib.boulder.ibm.com/infocenter/tivihelp/v8r1/topic * * /com.ibm.netcool_OMNIbus.doc_7.3.0/omnibus/wip/install/task/ * * omn_ha_configuringproxyfailover.html * ****************************************************************
Problem conclusion
The -Configuring proxy servers for failover- topic has been updated to include instructions for configuring high availability when the primary proxy server is run under process control. The solution to the problem is to point the primary proxy server to the virtual ObjectServer pair AGG_V. When the primary ObjectServer fails, events routed through PROXY_P are then sent to the backup ObjectServer.
Temporary fix
Comments
APAR Information
APAR number
IV24067
Reported component name
NETCOOL/OMNIBUS
Reported component ID
5724O4800
Reported release
730
Status
CLOSED DOC
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-06-28
Closed date
2012-07-11
Last modified date
2012-07-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSSHTQ","label":"Tivoli Netcool\/OMNIbus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"730","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
11 July 2012