Error description
Error Message: A java.lang.ExceptionInInitializerError could be received if the unnecessarily static initializer code in an Annotation class throws an exception (such as java.lang.RuntimeException). This issue only applies to Java 601. . Stack Trace: Exception in thread "main" java.lang.ExceptionInInitializerError at java.lang.J9VMInternals.initialize at java.lang.Class.forNameImpl(Native Method) at java.lang.Class.forName at com.ibm.oti.reflect.AnnotationParser.parseClass at com.ibm.oti.reflect.AnnotationParser.parseElementValue at com.ibm.oti.reflect.AnnotationParser.parseAnnotation at com.ibm.oti.reflect.AnnotationParser.parseAnnotations at java.lang.Class.getDeclaredAnnotations at java.lang.Class.getAnnotations at A.main Caused by: java.lang.RuntimeException at ReferencedClass.<clinit> at java.lang.J9VMInternals.initializeImpl(Native Method) at java.lang.J9VMInternals.initialize ... .
Local fix
This issue can be worked around by preventing the exception from the static initializer code in an Annotation class.
Problem summary
The problem is caused when the JVM unnecessarily executes static initializer code in an Annotation class.
Problem conclusion
This defect will be fixed in: 6.0.1 SR4 . The JVM has been updated so that the JVM would not unnecessarily execute static initializer code in an Annotation class.
Temporary fix
Comments
APAR Information
APAR number
IV23503
Reported component name
J9 COMMON CODE
Reported component ID
620700127
Reported release
260
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-06-22
Closed date
2012-06-22
Last modified date
2012-06-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
J9 COMMON CODE
Fixed component ID
620700127
Applicable component levels
R260 PSY
UP