APAR status
Closed as program error.
Error description
Error Message: N/A . Stack Trace: N/A . When the stress test was monitoring the time spent in the Garbage Collector the time would occasionally get smaller instead of increasing after a Garbage Collection event.
Local fix
N/A
Problem summary
If the clock on the machine is adjusted during a Garbage Collection event then there is a chance that the time spent in that GC event would appear to be negative.
Problem conclusion
This defect will be fixed in: 7.0.0 SR1 6.0.1 SR2 . The JVM has been updated so that it never decreases this value. If the delta ends up being negative due to clock skew or adjustment the JVM just ignores the time for this event.
Temporary fix
Comments
APAR Information
APAR number
IV19467
Reported component name
J9 COMMON CODE
Reported component ID
620700127
Reported release
260
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-04-10
Closed date
2012-04-10
Last modified date
2012-04-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
J9 COMMON CODE
Fixed component ID
620700127
Applicable component levels
R260 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSNVBF","label":"Runtimes for Java Technology"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]