Skip to main content

IV14200: XMLSTREAMWRITER MAY WRITE GARBAGE FOR WIN-125X ENCODINGS


Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Error Message: MALFORMED XML generated using STAX under IBM Java
    Runtime while working correctly with Oracle Java Runtime.
    .
    Stack Trace:
    .
    

Local fix

Problem summary

  • IBM StAX XMLStreamWriter might write a malformed Windows-1251
    encoded XML document on the second and subsequent usages of the
    XMLStreamWriter API.
    For example: Correct output from first use of the
    XMLStreamWriter:
    <?xml version="1.0" encoding="Windows-1251"?><env:Envelope
    xmlns:env="http://www.w3.org/2003/05/soap-envelope"><env:Header>
    </env:Header><env:Body><Object
    xmlns="urn:abc-de:fg:v1.0">Message</Object></env:Body></env:Enve
    lope>
    Incorrect output from second use of the XMLStreamWriter:
    <?xml version="1.0" encoding="Windows-1251"?>xenvtEnvelope
    xmlns:env="http://www.w3.org/2003/05/soap-envelopeD<HAT>00xenvtH
    eader<HAT>00</envtHeader<HAT>00xenvtBody<HAT>00xObject
    xmlns="urn:abc-de:fg:v1.0D<HAT>00Message</Object<HAT>00</envtBod
    y<HAT>00</envtEnvelope<HAT>00
    

Problem conclusion

  • This defect will be fixed in:
    6.0.0 SR10 FP1
    6.0.1 SR1 FP1
    7.0.0 SR1
    .
    IBM JVM has been updated to make correct encodings for
    XMLStreamWriter.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV14200

  • Reported component name

    XML/XSL

  • Reported component ID

    620700126

  • Reported release

    600

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-01-28

  • Closed date

    2012-02-23

  • Last modified date

    2012-05-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    XML/XSL

  • Fixed component ID

    620700126

Applicable component levels

  • R600 PSY

       UP

Rate this page:

(0 users)Average rating

Copyright and trademark information

IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.

Rate this page:


(0 users)Average rating

Add comments

Document information

Runtimes for Java Technology

XML


Software version:
6.0


Reference #:
IV14200


Modified date:
2012-05-28

Translate my page

Content navigation