APAR status
Closed as program error.
Error description
Error Message: N/A . Stack Trace: N/A . Development code drop for LIR19623(SDK626): Add RAS to PKCS11 JNI code.
Local fix
N/A
Problem summary
Not sufficient RAS code in PKCS#11 JNI code.
Problem conclusion
This defect will be fixed in: 6.0.1 SR2 . Added RAS tracing to PCKS#11 JNI code jpkcs11.c To turn on/off trace, issue the following: export HJV_PKCS11_TRACE=ON export HJV_PKCS11_TRACE=OFF The following were done in the code: - Added trace to most of the functions' entry and exit points; - Added trace to print out some functions' input parameters; - Added trace to print out return values for some functions that are traced and have meaningful output value; - Added trace to all calls to CALLSYNC to print out input parameters; - Added trace to some calls to CALLSYNC to print out return values.
Temporary fix
N/A
Comments
APAR Information
APAR number
IV12487
Reported component name
SECURITY
Reported component ID
620700125
Reported release
260
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-12-23
Closed date
2011-12-24
Last modified date
2012-05-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SECURITY
Fixed component ID
620700125
Applicable component levels
R260 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSNVBF","label":"Runtimes for Java Technology"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"260","Edition":"","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]