IBM Support

IT31478: HTTPREQUEST NODE REDIRECTION IS NOT WORKING WITH RELATIVE URL

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • If the redirection location in a 302 HTTP response is relative
    instead of an absolute URL, then HTTPRequest node fails to
    redirect the request.
    

Local fix

  • NA
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    <span style="background-color:rgb(255, 255, 255)">All users of
    IBM Integration Bus v10 and IBM App Connect Enterprise v11 with
    HTTPRequest node. </span>
    
    
    Platforms affected:
    z/OS, MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    <span style="background-color:rgb(255, 255, 255)">If the
    Location header in a 302 HTTP response is a relative URL, then
    the HTTPRequest node fails to redirect the request.
    
    Here is an example of http response with relative URL</span>
    
    HTTP<span style="color:rgb(102, 102, 102)">/</span><span
    style="color:rgb(102, 102, 102)">1.1</span><span
    style="background-color:rgb(255, 255, 255)"> </span><span
    style="color:rgb(102, 102, 102)">302</span><span
    style="background-color:rgb(255, 255, 255)"> </span>Found
    <span style="color:rgb(125, 144, 41)">Location</span><span
    style="color:rgb(102, 102, 102)">:</span><span
    style="background-color:rgb(255, 255, 255)"> </span>/articles/
    
    
    <span style="background-color:rgb(255, 255, 255)">Following is
    an http response with an absolute URL that works </span>
    
    HTTP<span style="color:rgb(102, 102, 102)">/</span><span
    style="color:rgb(102, 102, 102)">1.1</span> <span
    style="color:rgb(102, 102, 102)">302</span> Found
    <span style="color:rgb(125, 144, 41)">Location</span><span
    style="color:rgb(102, 102, 102)">:</span>
    http://www.example.org/index.php
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IT31478

  • Reported component name

    INTEGRATION BUS

  • Reported component ID

    5724J0540

  • Reported release

    A00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-01-10

  • Closed date

    2020-06-03

  • Last modified date

    2020-06-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INTEGRATION BUS

  • Fixed component ID

    5724J0540

Applicable component levels

  • RA00 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
12 June 2020